Quest-diagnostics QUESTEMP 36 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Tiskárny Quest-diagnostics QUESTEMP 36. Quest Diagnostics QUESTEMP 36 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 14
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
QUESTemp° 36
Thermal Environment Monitor
Operator’s Manual
Note: Due to the new ATEX Directive in Europe, all
references in this document to "Ex" or "EEx" for
intrinsic safety approvals should be disregarded
effective 7/1/03 within the member countries of the
European Union (EU). At this time, this product is
not approved in accordance with the new ATEX
Directive and is not sold for use in hazardous
atmospheres or explosive zones by customers
within the EU. Outside of the EU, all references to
intrinsic safety continue without change
.
2
Copyright 9/2001
Revision B
P/N 056-663
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - Operator’s Manual

QUESTemp° 36 Thermal Environment Monitor Operator’s Manual Note: Due to the new ATEX Directive in Europe, all references in this document to

Strany 2 - COMFORT

19battery. If the rechargeable battery pack ever needs to be replaced, it can be accessed by removing the screws from the bottom panel of the unit.

Strany 3 - 3. MEASUREMENTS

21Remote Sensor Bars: 2 x 15pin D-sub jacks are located on the side of the unit for plugging in 1 or 2 additional sensor bars by using remote cables

Strany 4 - SETUP RESET

23ACGIH CLOTHING CORRECTIONS The following clothing corrections are in degrees Celsius. When a clothing correction is entered into the setup portio

Strany 5 - DRY 92.2°F *

25 ELECTRICAL POWER RESEARCH INSTITUTE The recommended working hours are shown based on a maximum of four hours. A time of 4:01 indicates greater

Strany 6 - 8. PRINTING

2718. QUEST SERVICE AND WARRANTY POLICY Service Information Congratulations! You have purchased one of the finest instruments available, manufactu

Strany 7 - SAMPLE PRINTOUT

3TABLE OF CONTENTS 1. UP AND RUNNING... 5 2. USING THE QUESTEMP...

Strany 8 - 11. AIRFLOW

51. UP AND RUNNING 1. Make sure the wet bulb’s wick is clean. Fill the reservoir with distilled water. 2. Place the QUESTemp in the work area

Strany 9 - 14. POWER OPTIONS

7The Heat Index is defined over a temperature range of 70°F - 120°F (21°C - 49°C) and a relative humidity range of 30% - 99%. Outside of this range,

Strany 10 - 15. SPECIFICATIONS

9PRINT Allows printing to a parallel or serial printer or to a computer. The unit will recognize the cable plugged in and configure itself for seria

Strany 11

11 A series of dashes appear in the display if one of the following occur: • the Heat Index or Humidex is outside of its allowable range • the temper

Strany 12 - UNITED STATES NAVY

13SAMPLE PRINTOUT QUEST TECHNOLOGIES Page 1 HEAT STRESS REPORT File Name

Strany 13 - Air Probe Accessories

159. PC COMMUNICATIONS The QUESTemp°36 has the flexibility to be set up and controlled through computer software. The programmable start and stop

Strany 14 - Warranty Policy

17 OPERATING SEQUENCE 1. Turn FLOW ON in the setup menu of the Questemp°36. 2. Plug the Air Probe into the port labeled FLOW on the side of the Que

Komentáře k této Příručce

Žádné komentáře